IEEE 317-2013 PDF
This standard prescribes the requirements for the design, construction, qualification, test, and installation of electric penetration assemblies in nuclear containment structures for stationary nuclear power generating stations. The requirements for external circuits that connect to penetration assemblies are beyond the scope of this standard. This standard does not include requirements for operation, maintenance, or periodic testing after installation.
This standard presents criteria to facilitate the determination of the features of design, construction, test, qualification, and installation relative to the electric penetration assemblies of primary containments of nuclear facilities.
Revision Standard – Inactive-Reserved. An electric penetration assembly is an assembly of insulated electric conductors, conductor seals, module seals (if any), and aperture seals that provides the passage of the electric conductors through a single aperture in the nuclear containment structure, while providing a pressure barrier between the inside and the outside of the containment structure. The electric penetration assembly includes terminal (junction) boxes, terminal blocks, connectors and cable supports, and splices which are designed and furnished as an integral part of the assembly. Requirements for the design, construction, qualification, test, and installation of electric penetration assemblies in nuclear containment structures for stationary nuclear power generating stations are prescribed in this standard.