AWS A5.22/A5.22M PDF
This specification prescribes requirements for the classification of flux cored stainless steel electrodes for flux cored arc welding, flux cored stainless steel rods for root pass welding with the gas tungsten arc process, and metal cored stainless steel electrodes for gas metal arc welding, gas tungsten arc welding, plasma arc welding, submerged arc welding, and any other process to which they may be applied.
The chromium content of undiluted weld metal from these electrodes and rods is not less than 10.5% nominal and the iron content exceeds that of any other element. For purposes of classification, the iron content shall be derived as the balance element when all other elements are considered to be set at their specified minimum values.
This specification uses both U.S. Customary Units and the International System of Units (SI). The measurements are not exact equivalents; therefore, each system must be used independently of the other without combining in any way when referring to material properties. The specification with the designation A5.22 uses U.S. Customary Units. The specification A5.22M uses SI Units. The latter are shown within brackets ([ ]) or in appropriate columns in tables. Standard dimensions based on either system may be used for sizing of filler metals or packaging or both under A5.22 or A5.22M specifications.
Safety and health issues are beyond the scope of this standard; some safety and health information is provided, but such issues are not fully addressed herein. Some safety and health information can be found in Annex Clauses A5 and A11.
Safety and health information is available from the following sources:
American Welding Society:
(1) ANSI Z49.1, Safety in Welding, Cutting, and Allied Processes
(2) AWS Safety and Health Fact Sheets
(3) Other safety and health information on the AWS website
Material or Equipment Manufacturers:
(1) Safety Data Sheets supplied by materials manufacturers
(2) Operating Manuals supplied by equipment manufacturers
Applicable Regulatory Agencies
Work performed in accordance with this standard may involve the use of materials that have been deemed hazardous and may involve operations or equipment that may cause injury or death. This standard does not purport to address all safety and health risks that may be encountered. The user of this standard should establish an appropriate safety program to address such risks as well as to meet applicable regulatory requirements. ANSI Z49.1 should be considered when developing the safety program.