ASTM D3694-96(2024) PDF
1.1These practices cover the various means of (1) preparing sample containers used for collection of waters to be analyzed for organic constituents and (2) preservation of such samples from the time of sample collection until the time of analysis.
1.2The sample preservation practice is dependent upon the specific analysis to be conducted. See Section 9 for preservation practices listed with the corresponding applicable general and specific constituent test method. The preservation method for waterborne oils is given in Practice D3325. Use of the information given herein will make it possible to choose the minimum number of sample preservation practices necessary to ensure the integrity of a sample designated for multiple analysis. For further considerations of sample preservation, see the Manual on Water.2
1.3The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 6.7, 6.24, and 8.1.3.
1.5This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.