AS 1530.8.1:2018 PDF
This Standard provides methods for determining the performance of external construction elements when exposed to radiant heat, burning embers and burning debris.
NOTES:
1 The methods do not simulate engulfment by flames from the fire front or large burning items such as other burning buildings or adjacent isolated trees and shrubs (see AS 1530.8.2).
2 The peak level of radiant heat exposure is dependent upon the distance of the building from the potential fire front, the fire severity and the extent of shielding. The peak level can be based on an analysis of the specific site from first principles or from the classification of the site in accordance with the simple methods specified in AS 3959.
3 The results of the fire tests may be used to directly assess fire hazard, but it should be recognized that a single test method will not provide a full assessment of fire hazard under all fire conditions.
4 The fire tests in this Standard provide data relating to the performance of the particular element and building system and do not provide a general assessment of the performance of a specific type of material.